Nidek NT-530P is purpose-built for modern optometry clinics, offering both non-contact tonometry and optical pachymetry in a single device. Optometrists can measure intraocular pressure and corneal thickness without contact, streamlining glaucoma screening and routine eye exams.
The NT-530P automatically corrects pressure values using the Shah, Ehlers, or Dresden formulas to improve clinical accuracy. Pachymetry results are calculated from a Scheimpflug image, clearly displayed on screen and easily exported for records or referrals—enhancing workflow and patient care in the optometry clinic.
The NT-530P is purpose-built for modern optometry clinics, featuring Automatic Puff Control (APC) technology that automatically adjusts the air jet to the patient’s intraocular pressure. This ensures gentle, comfortable measurements and a quieter exam experience for every patient.
Features
- * Automatic Puff Control (APC): Delivers gentle, comfortable air-puff measurements for optimal patient experience in the optometry clinic.
- * Artificial Intelligence (AI): Selects the best measurement values and finalizes the test automatically, ensuring precision and workflow efficiency for optometrists.
- * Automatic 3D tracking: Maintains precise alignment and positioning, streamlining the measurement process and reducing operator fatigue.
- * Automatic IOP compensation: Corrects pressure readings based on corneal thickness for more accurate glaucoma assessment.
- * Scheimpflug-based pachymetry: Provides precise, non-contact corneal thickness measurements for comprehensive exams.
- * Proximity warning: On-screen and audible alerts help keep exams safe for every patient.
- * 3D tracking & auto-triggering: Enable quick, accurate measurements for high-volume optometry clinics.
- * Adjustable mechanical stop: Prevents accidental contact with the eye for additional safety and peace of mind.
A built-in Artificial Intelligence (AI) function selects the most accurate measurement values and automatically finalizes each test. Combined with 3D automatic tracking and auto-triggering, this technology gives optometrists exceptional precision, reliability, and user-friendly operation—making routine IOP and pachymetry screening faster and more consistent.
Automatic IOP compensation based on corneal thickness is built in, so optometrists can provide corrected readings that account for each patient’s anatomy—critical for accurate glaucoma screening and management.
Central corneal thickness is measured precisely using the Scheimpflug principle, while 3D tracking and auto-triggering make the process fast and seamless—helping optometrists obtain comprehensive corneal assessments with minimal effort.
Patient safety is prioritized with on-screen and audible alerts if the air jet nozzle approaches too closely, plus an adjustable mechanical stop to prevent contact. These safeguards give both optometrists and patients added peace of mind during exams.
Technische Details
- * Measurement range: 1 to 60 mmHg
- * APC measurement parameters: 40 / APC 60 / 40 / 60 (APC= “Automatic Puff Control”)
- * Working distance: 11 mm
- * Non-contact pachymetry: Yes
- * Measuring range (Pachymetry): 150 to 1300 µm
- * Power supply: AC 100-240 V ± 10%, 50/60 Hz
- * Power consumption: 100 VA
- * Dimensions: 260 (W) x 481 (D) x 474 (H) mm
- * Weight : 20 Kg
Referenz