{"id":18049,"date":"2026-05-21T07:49:32","date_gmt":"2026-05-21T07:49:32","guid":{"rendered":"https:\/\/ferrisoptical.com\/?post_type=product&#038;p=18049"},"modified":"2026-07-02T05:19:02","modified_gmt":"2026-07-02T05:19:02","slug":"tomey-ud-8000-b-scan","status":"publish","type":"product","link":"https:\/\/ferrisoptical.com\/de\/product\/tomey-ud-8000-b-scan\/","title":{"rendered":"TOMEY UD-8000 B-Scan"},"content":{"rendered":"<p><span style=\"box-sizing: border-box; margin: 0px; padding: 0px;\"><strong>TOMEY UD-8000 B-Scan<\/strong> provides ease of operation and performance accuracy for optometrists and ophthalmologists alike, featuring intuitive touch-screen controls, including video recording and analysis functions.<\/span><\/p>\n<p>The Ultrasonic B Scanner UD-8000 is a unique B-scan device with a \u201cFull Digital System\u201d in which the A\/D converter is located between the transducer array and the delay circuit. The in-phase synthetic method, digital wave detection for higher resolution, and the new \u201ctissue harmonic imaging\u201d filtering method for finer images are results of this digital system.<\/p>\n<p>The UD-800 was developed to satisfy all your expectations. Features like the new-generation annular array probes, high-resolution touch-screen operation, and data communication via USB or LAN make this device easy to handle and efficient and fast in operation. Simply choose all the features you need! With its included 10 MHz unique 2-ring array B-Scan probe and the A-Scan biometry probe, the UD-800 is a fantastic basic tool for high-end performance.<\/p>\n<p>An intuitive software guides you through all measurements, which can be printed out (on internal and external printers). Or simply save the data to the internal database or to the PC. With the DICOM conform export, hospital networks are no problem anymore, or just a simple pure data export; it is your choice.<\/p>\n<div style=\"height: 0px; overflow: hidden; padding-top: 56.25%; position: relative; width: 100%;\"><iframe style=\"position: absolute; top: 0px; left: 0px; width: 100%; height: 100%;\" title=\"YouTube-Videoplayer\" src=\"https:\/\/tube.rvere.com\/embed?v=VOMWPLV7Stc\" frameborder=\"0\" allowfullscreen=\"allowfullscreen\"><br \/>\n<\/iframe><\/div>\n<p>&nbsp;<\/p>\n<h2>Features:<\/h2>\n<div class=\"row\">\n<div class=\"col-sm-6\">\n<div class=\"panel panel-primary\">\n<div class=\"panel-body\">\n<ul>\n<li>Unique Probe and Component<\/li>\n<li>Switching frequency in 15MHz B-Probe<\/li>\n<li>Optional: 60MHz (UBM) Probe,\u00a0 A-Probe\/A-Diagnostic<\/li>\n<li>Digital Wave Detection for Higher-Resolution<\/li>\n<li>15\u201c TFT Color Touch Screen Operation<\/li>\n<li>Automated Video Recording<\/li>\n<li>On-Screen Annotation<\/li>\n<li>Membrane Cap ( Disposable)<\/li>\n<li>USB Memory<\/li>\n<\/ul>\n<h4 class=\"text-primary\">Complete probe selection<\/h4>\n<p>Decide for more options now or later \u2013 with the optional 40 MHz linear UBM or 20 MHz Pachymetry probe \u2013 they are all easy to attach. Even an A-diagnostic with the log, linear, or S-mode is no problem.<\/p>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"col-sm-6\">\n<div class=\"panel panel-primary\">\n<div class=\"panel-body\">\n<h4 class=\"text-primary\">Unique 10 MHZ 2-ring array B-probe<\/h4>\n<p>Advanced vitreous diagnostic examination due to our new optimised wide field tissue penetration mode.<\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"row\">\n<div class=\"col-sm-6\">\n<div class=\"panel panel-primary\">\n<div class=\"panel-body\">\n<h4 class=\"text-primary\">40 MHZ UBM (OPTIONAL)<\/h4>\n<p>Membrane waterproofed cap (disposable) provides fast and easy testing without the need of a water bath. Due to this technology you are able to examine your patient in an upright position with much more comfort \u2013 for you and your patient.<\/p>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"col-sm-6\">\n<div class=\"panel panel-primary\">\n<div class=\"panel-body\">\n<h4 class=\"text-primary\">INTERNAL DATABASE<\/h4>\n<p>You can simply save the data on the internal database or on the PC.<br \/>\nIntuitive software guides all measurement results, which can be printed out through the built-in printer or an external printer.<br \/>\nIt is also possible to save the data (up to 52,000 eyes) to the internal database and the PC. With the DICOM format, hospital intranetworks become efficient. Data export (CSV or JPEG) is available.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-18058\" src=\"https:\/\/ferrisoptical.com\/wp-content\/uploads\/2026\/05\/TOMEY-UD-8000.jpg\" alt=\"TOMEY-UD-8000\" width=\"1024\" height=\"768\" srcset=\"https:\/\/ferrisoptical.com\/wp-content\/uploads\/2026\/05\/TOMEY-UD-8000.jpg 1024w, https:\/\/ferrisoptical.com\/wp-content\/uploads\/2026\/05\/TOMEY-UD-8000-300x225.jpg 300w, https:\/\/ferrisoptical.com\/wp-content\/uploads\/2026\/05\/TOMEY-UD-8000-768x576.jpg 768w, https:\/\/ferrisoptical.com\/wp-content\/uploads\/2026\/05\/TOMEY-UD-8000-1000x750.jpg 1000w, https:\/\/ferrisoptical.com\/wp-content\/uploads\/2026\/05\/TOMEY-UD-8000-310x233.jpg 310w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<h2>Spezifikationen<\/h2>\n<div class=\"row\">\n<div class=\"col-sm-6\">\n<table class=\"table table-bordered table-condensed\">\n<tbody>\n<tr>\n<td class=\"danger\" colspan=\"2\">\n<h3>10 MHZ B-PROBE<br \/>\n2-RING SECTOR SCANNING<\/h3>\n<\/td>\n<\/tr>\n<tr>\n<td>Frame rate basic mode<\/td>\n<td>20 frames \/ sec<\/td>\n<\/tr>\n<tr>\n<td>Maximum number of pages in a movie<\/td>\n<td>200 pages x 2<\/td>\n<\/tr>\n<tr>\n<td>Image display range Standard<\/td>\n<td>35.2 mm \/ 52\u00b0 (at ultrasound velocity = 1,550 m \/ sec)<\/td>\n<\/tr>\n<tr>\n<td>Wide<\/td>\n<td>48.0 mm \/ 52\u00b0 (at ultrasound velocity = 1,550 m \/ sec)<\/td>\n<\/tr>\n<tr>\n<td>Axial &amp; lateral resolution \/ accuracy<\/td>\n<td>0.6 mm \/ \u00b10.5 mm<\/td>\n<\/tr>\n<tr>\n<td>Acoustic lines<\/td>\n<td>131 lines (step by 0.4\u00b0)<\/td>\n<\/tr>\n<tr>\n<td>Colour scale<\/td>\n<td>256 scale level<\/td>\n<\/tr>\n<tr>\n<td class=\"danger\" colspan=\"2\">\n<h3>40 MHZ UBM PROBE<br \/>\nSINGLE LINEAR SCANNING<\/h3>\n<\/td>\n<\/tr>\n<tr>\n<td>Frame rate basic mode<\/td>\n<td>10 frame \/ sec<\/td>\n<\/tr>\n<tr>\n<td>Maximum number of pages in a movie<\/td>\n<td>100 pages x 2<\/td>\n<\/tr>\n<tr>\n<td>Image display range<\/td>\n<td>9 mm (W) x 7mm (D) (at 1,550 m \/ sec)<\/td>\n<\/tr>\n<tr>\n<td>Axial &amp; lateral resolution \/ accuracy<\/td>\n<td>0.05 mm \/ \u00b10.1 mm<\/td>\n<\/tr>\n<tr>\n<td>Minimum distance unit between cursors<\/td>\n<td>0.02 mm step (at 1,550 m \/ sec)<\/td>\n<\/tr>\n<tr>\n<td>Acoustic lines<\/td>\n<td>450 lines (step by 0.02 mm)<\/td>\n<\/tr>\n<tr>\n<td>Colour scale<\/td>\n<td>256 scale level<\/td>\n<\/tr>\n<tr>\n<td class=\"danger\" colspan=\"2\">\n<h3>BIOMETRY 10 MHZ SOLID STATE PROBE WITH BUILT IN RED FIXATION LED<\/h3>\n<\/td>\n<\/tr>\n<tr>\n<td>Measurement range<\/td>\n<td>45.00 mm<\/td>\n<\/tr>\n<tr>\n<td>Measurement resolution \/ accuracy<\/td>\n<td>0.01 mm \/ \u00b10.1 mm<\/td>\n<\/tr>\n<tr>\n<td>IOL power calculation<\/td>\n<td>Haigis standard<br \/>\nHaigis optimised<br \/>\nHoffer \u00aeQ<br \/>\nHolladay 1<br \/>\nSRK II<br \/>\nSRK\/T<br \/>\nSRK SHOWA<br \/>\nShammas-PL<br \/>\nSRK\/T Double K<\/td>\n<\/tr>\n<tr>\n<td class=\"danger\" colspan=\"2\">\n<h3>A-SCAN DIAGNOSIS 10 MHZ SOLID STATE PROBE<\/h3>\n<\/td>\n<\/tr>\n<tr>\n<td>Measurement range<\/td>\n<td>60 mm<\/td>\n<\/tr>\n<tr>\n<td>Measurement resolution \/ accuracy<\/td>\n<td>0.01 mm \/ \u00b10.1 mm<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<p>&nbsp;<\/p>\n<p>The main unit<span style=\"box-sizing: border-box; margin: 0px; padding: 0px;\">, with a B-scan probe, printer, foot pedal, and\u00a0<a href=\"https:\/\/ferrisoptical.com\/de\/produkt\/tomey-al-4000-biometer-and-pachymeter\/\" target=\"_blank\" rel=\"noopener\">Tomey AL-4000,<\/a> is available separately for A-scan use<\/span>.<\/p>\n<h2>Referenz<\/h2>\n<ul>\n<li><a href=\"https:\/\/ferrisoptical.com\/wp-content\/uploads\/2026\/05\/tomey-UD-8000_brochure.pdf\">Brosch\u00fcre<\/a><\/li>\n<\/ul>","protected":false},"excerpt":{"rendered":"<p>The TOMEY UD-8000 B-Scan is an ophthalmic ultrasound system designed to help clinicians evaluate the posterior segment when a clear view is difficult due to dense cataract, vitreous opacity, hemorrhage, trauma, or corneal opacity.<\/p>","protected":false},"featured_media":18050,"comment_status":"closed","ping_status":"closed","template":"","meta":{"rs_blank_template":"","rs_page_bg_color":"","slide_template_v7":""},"product_brand":[],"product_cat":[171],"product_tag":[172],"class_list":["post-18049","product","type-product","status-publish","has-post-thumbnail","product_cat-ophthalmic-ultrasound","product_tag-tomey-ud-8000","ts_product_brand-tomey","first","instock","sale","shipping-taxable","purchasable","product-type-simple"],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.9 (Yoast SEO v27.9) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>TOMEY UD-8000 B-Scan - FERRIS OPTICAL<\/title>\n<meta name=\"description\" content=\"TOMEY UD-8000 B-Scan ultrasound supports posterior segment imaging when media opacity limits direct view. Ideal for retina, cataract, and ophthalmology clinics.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/ferrisoptical.com\/de\/produkt\/tomey-ud-8000-b-scan\/\" \/>\n<meta property=\"og:locale\" content=\"de_DE\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"TOMEY UD-8000 B-Scan\" \/>\n<meta property=\"og:description\" content=\"TOMEY UD-8000 B-Scan ultrasound supports posterior segment imaging when media opacity limits direct view. Ideal for retina, cataract, and ophthalmology clinics.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/ferrisoptical.com\/de\/produkt\/tomey-ud-8000-b-scan\/\" \/>\n<meta property=\"og:site_name\" content=\"FERRIS OPTICAL\" \/>\n<meta property=\"article:modified_time\" content=\"2026-07-02T05:19:02+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/ferrisoptical.com\/wp-content\/uploads\/2026\/05\/TOMEY-UD-8000-For-Sale-1.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"800\" \/>\n\t<meta property=\"og:image:height\" content=\"1067\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Preis\" \/>\n\t<meta name=\"twitter:data1\" content=\"&#036;6,999.00\" \/>\n\t<meta name=\"twitter:label2\" content=\"Verf\u00fcgbarkeit\" \/>\n\t<meta name=\"twitter:data2\" content=\"Auf Lager\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/ferrisoptical.com\\\/product\\\/tomey-ud-8000-b-scan\\\/\",\"url\":\"https:\\\/\\\/ferrisoptical.com\\\/product\\\/tomey-ud-8000-b-scan\\\/\",\"name\":\"TOMEY UD-8000 B-Scan - FERRIS OPTICAL\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/ferrisoptical.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/ferrisoptical.com\\\/product\\\/tomey-ud-8000-b-scan\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/ferrisoptical.com\\\/product\\\/tomey-ud-8000-b-scan\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/ferrisoptical.com\\\/wp-content\\\/uploads\\\/2026\\\/05\\\/TOMEY-UD-8000-For-Sale-1.jpg\",\"datePublished\":\"2026-05-21T07:49:32+00:00\",\"dateModified\":\"2026-07-02T05:19:02+00:00\",\"description\":\"TOMEY UD-8000 B-Scan ultrasound supports posterior segment imaging when media opacity limits direct view. Ideal for retina, cataract, and ophthalmology clinics.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/ferrisoptical.com\\\/product\\\/tomey-ud-8000-b-scan\\\/#breadcrumb\"},\"inLanguage\":\"de\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/ferrisoptical.com\\\/product\\\/tomey-ud-8000-b-scan\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"de\",\"@id\":\"https:\\\/\\\/ferrisoptical.com\\\/product\\\/tomey-ud-8000-b-scan\\\/#primaryimage\",\"url\":\"https:\\\/\\\/ferrisoptical.com\\\/wp-content\\\/uploads\\\/2026\\\/05\\\/TOMEY-UD-8000-For-Sale-1.jpg\",\"contentUrl\":\"https:\\\/\\\/ferrisoptical.com\\\/wp-content\\\/uploads\\\/2026\\\/05\\\/TOMEY-UD-8000-For-Sale-1.jpg\",\"width\":800,\"height\":1067,\"caption\":\"TOMEY UD 8000\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/ferrisoptical.com\\\/product\\\/tomey-ud-8000-b-scan\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/ferrisoptical.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Shop\",\"item\":\"https:\\\/\\\/ferrisoptical.com\\\/ophthalmic-equipment\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"TOMEY UD-8000 B-Scan\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/ferrisoptical.com\\\/#website\",\"url\":\"https:\\\/\\\/ferrisoptical.com\\\/\",\"name\":\"FERRIS OPTICAL\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/ferrisoptical.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"de\"}]}<\/script>\n<meta property=\"product:price:amount\" content=\"6999.00\" \/>\n<meta property=\"product:price:currency\" content=\"USD\" \/>\n<meta property=\"og:availability\" content=\"instock\" \/>\n<meta property=\"product:availability\" content=\"instock\" \/>\n<meta property=\"product:retailer_item_id\" content=\"TOMEY UD-8000\" \/>\n<meta property=\"product:condition\" content=\"new\" \/>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"TOMEY UD-8000 B-Scan - FERRIS OPTICAL","description":"TOMEY UD-8000 B-Scan ultrasound supports posterior segment imaging when media opacity limits direct view. Ideal for retina, cataract, and ophthalmology clinics.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/ferrisoptical.com\/de\/produkt\/tomey-ud-8000-b-scan\/","og_locale":"de_DE","og_type":"article","og_title":"TOMEY UD-8000 B-Scan","og_description":"TOMEY UD-8000 B-Scan ultrasound supports posterior segment imaging when media opacity limits direct view. Ideal for retina, cataract, and ophthalmology clinics.","og_url":"https:\/\/ferrisoptical.com\/de\/produkt\/tomey-ud-8000-b-scan\/","og_site_name":"FERRIS OPTICAL","article_modified_time":"2026-07-02T05:19:02+00:00","og_image":[{"width":800,"height":1067,"url":"https:\/\/ferrisoptical.com\/wp-content\/uploads\/2026\/05\/TOMEY-UD-8000-For-Sale-1.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_misc":{"Preis":"&#36;6,999.00","Verf\u00fcgbarkeit":"Auf Lager"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/ferrisoptical.com\/product\/tomey-ud-8000-b-scan\/","url":"https:\/\/ferrisoptical.com\/product\/tomey-ud-8000-b-scan\/","name":"TOMEY UD-8000 B-Scan - FERRIS OPTICAL","isPartOf":{"@id":"https:\/\/ferrisoptical.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/ferrisoptical.com\/product\/tomey-ud-8000-b-scan\/#primaryimage"},"image":{"@id":"https:\/\/ferrisoptical.com\/product\/tomey-ud-8000-b-scan\/#primaryimage"},"thumbnailUrl":"https:\/\/ferrisoptical.com\/wp-content\/uploads\/2026\/05\/TOMEY-UD-8000-For-Sale-1.jpg","datePublished":"2026-05-21T07:49:32+00:00","dateModified":"2026-07-02T05:19:02+00:00","description":"TOMEY UD-8000 B-Scan ultrasound supports posterior segment imaging when media opacity limits direct view. Ideal for retina, cataract, and ophthalmology clinics.","breadcrumb":{"@id":"https:\/\/ferrisoptical.com\/product\/tomey-ud-8000-b-scan\/#breadcrumb"},"inLanguage":"de","potentialAction":[{"@type":"ReadAction","target":["https:\/\/ferrisoptical.com\/product\/tomey-ud-8000-b-scan\/"]}]},{"@type":"ImageObject","inLanguage":"de","@id":"https:\/\/ferrisoptical.com\/product\/tomey-ud-8000-b-scan\/#primaryimage","url":"https:\/\/ferrisoptical.com\/wp-content\/uploads\/2026\/05\/TOMEY-UD-8000-For-Sale-1.jpg","contentUrl":"https:\/\/ferrisoptical.com\/wp-content\/uploads\/2026\/05\/TOMEY-UD-8000-For-Sale-1.jpg","width":800,"height":1067,"caption":"TOMEY UD 8000"},{"@type":"BreadcrumbList","@id":"https:\/\/ferrisoptical.com\/product\/tomey-ud-8000-b-scan\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/ferrisoptical.com\/"},{"@type":"ListItem","position":2,"name":"Shop","item":"https:\/\/ferrisoptical.com\/ophthalmic-equipment\/"},{"@type":"ListItem","position":3,"name":"TOMEY UD-8000 B-Scan"}]},{"@type":"WebSite","@id":"https:\/\/ferrisoptical.com\/#website","url":"https:\/\/ferrisoptical.com\/","name":"FERRIS OPTICAL","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/ferrisoptical.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"de"}]},"product_price_amount":"6999.00","product_price_currency":"USD","og_availability":"instock","product_availability":"instock","product_retailer_item_id":"TOMEY UD-8000","product_condition":"new"},"_links":{"self":[{"href":"https:\/\/ferrisoptical.com\/de\/wp-json\/wp\/v2\/product\/18049","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/ferrisoptical.com\/de\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/ferrisoptical.com\/de\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/ferrisoptical.com\/de\/wp-json\/wp\/v2\/comments?post=18049"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/ferrisoptical.com\/de\/wp-json\/wp\/v2\/media\/18050"}],"wp:attachment":[{"href":"https:\/\/ferrisoptical.com\/de\/wp-json\/wp\/v2\/media?parent=18049"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/ferrisoptical.com\/de\/wp-json\/wp\/v2\/product_brand?post=18049"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/ferrisoptical.com\/de\/wp-json\/wp\/v2\/product_cat?post=18049"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/ferrisoptical.com\/de\/wp-json\/wp\/v2\/product_tag?post=18049"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}